LS5000
Australian Designed & Manufactured Home
Site map
Contact us





     
 


LS Series - Sinewave Inverter
options

Download Pricelist LS Retail Pricelist Aust. (124kB)

Other AC Output and DC Input Voltages
As an alternative to 230 V AC 50 Hz, the output can be 100-120VAC 50/60 Hz. DC Input voltages are available in a range from 12V DC to 125V DC.


Nominal DC Input voltage and voltage range
Inverter Size and Model
12V (10-17)
24V (21-34)
32V  (28-45)
36V (32-51)
48V (42-68)
72V (63-102)
110V (80-140)
125V (96-160)
500W     (LS512)
[
-
-
-
-
-
-
-
600W     (LS6XX)
-
[
-
-
[
-
[
[
1000W    (LS1012)
[
-
-
-
-
-
-
-
1200W     (LS12XX)
-
[
[
[
[
[
[
[
1500W     (LS1512)
[
-
-
-
-
-
-
-
1800W     (LS18XX)
-
[
[
[
[
[
[
[
2000W     (LS2012)
[
-
-
-
-
-
-
-
2300W     (LS23XX)
-
[
- - - - - -
2500W     (LS25XX) - - [ [ [ [ [ [
3000W     (LS30XX)
-
[
-
- -
-
- -
3500W     (LS3548)
-
-
[ [ [
-
[ [
5000W     (LS5048)
-
-
-
-
[
-
-
-
7000W     (LS7048) - - - - [ - - -


Conformal-coating of circuit boards to Mil Spec MIL-I-46058C

Reduces the effects of harsh environments such as salt spray on electronic components.

Vibration Proofing
Special attention is given to components which might become suspect to vibration damage. Additional fixing points and extra protection is provided. "Ruggedised" Latronics® Inverters have been used extensively by Railways and Service Vehicles throughout Australia.

Transfer Switch (extra j-box included)
When fitted with this option the AC output is switched between mains AC and Inverter AC. An auxiliary AC source can be connected to the mains input junction box on the rear of the inverter. While this AC source is present, it will be connected to the AC output junction box on the rear and the power outlet on the front. Should the auxiliary AC source fail, the changeover switch automatically diverts the Inverter's AC source to the AC output junction box on the rear and power outlet on the front. 
Details

Alarm Contact Output (extra j-box included)
The alarm output is provided by a relay contact. Wiring is via fixed terminals located in the junction box marked "Alarm Output" on the rear of the Inverter. The relay contact changes state when the Inverter's AC output is not present.

Automatic Reset (Standard)
In unattended situations where total shutdown is not desirable, the automatic reset option can be selected. Should the Inverter shut down due to under voltage, over temperature or any fault condition, the Inverter is reset every eight minutes (other settings available on request) until the fault condition clears (for example Inverter cools or batteries recharge) and operation resumes.
See Manual for Details

50/60Hz (Standard)
If you need to operate American equipment this option will allow your Inverter to operate at 60HZ.
See Manual for Details